Parameters/Test conditions
|
Min
|
Typ.
|
Max
|
Unit
|
Note
|
1
|
Signal Operating Wavelength
|
1000
|
1064
|
1100
|
nm
|
|
2
|
Pump Operating Wavelength
|
800
|
|
1000
|
nm
|
|
3
|
Pump Fiber
|
Core Diameter
|
|
105
|
|
µm
|
Refer to fiber codes
|
4
|
Cladding Diameter
|
|
125
|
|
µm
|
5
|
Numerical Aperture
|
0.22
|
-
|
6
|
Signal Fiber
|
PM 10/125 SCF or PM 10/125 DCF
|
Refer to fiber codes
|
|
Pump Efficiency (%)
|
Signal Insertion Loss (dB)
|
Power Handling
(W, each port)
|
7
|
Output Fiber
|
PM 10/125 DCF
|
>88(Typ. 92)
|
<0.7(Typ. 0.5)
|
25
|
PM 12/125 DCF
|
>88(Typ. 92)
|
<0.7(Typ. 0.5)
|
25
|
PM 15/125 DCF
|
>88(Typ. 92)
|
<0.7(Typ. 0.5)
|
25
|
PM 20/125 DCF
|
>88(Typ. 92)
|
<0.7(Typ. 0.5)
|
25
|
PM 20/200 DCF
|
>93(Typ. 95)
|
<0.7(Typ. 0.5)
|
25
|
PM 25/250 DCF
|
>93(Typ. 95)
|
<0.7(Typ. 0.5)
|
25
|
PM 30/250 DCF
|
>93(Typ. 95)
|
<0.7(Typ. 0.5)
|
25
|
PM 20/400 DCF
|
>95(Typ. 97)
|
<0.7(Typ. 0.5)
|
25
|
8
|
PER
|
18
|
|
|
dB
|
|
9
|
M2
|
|
|
1.3
|
-
|
|
10
|
Optical Isolation
|
20
|
|
|
dB
|
|
11
|
Fiber Length
|
0.8
|
|
|
m
|
Each port
|
12
|
Operating Environment Temperature
|
-5
|
|
+70
|
oC
|
|
13
|
Operating Humidity
|
5
|
|
95
|
%RH
|
Not recommend in high humidity for long time.
|
14
|
Storage Temperature
|
-40
|
|
+85
|
oC
|
|
15
|
Package
|
70x12x8mm or per handling power
|
-
|
Handling power is different with PKG
|